Compressed Air Leak Survey Report Template

A compressed air leak survey report should document where each leak was found, how it was measured, estimated air and energy loss, repair status, and the result of post-repair verification.

Use the structure below as a working report, not a description of compressed air. Fill it on paper, in a spreadsheet, or record the same fields in the Compressed Air Leak Survey Tool.

What Should a Compressed Air Leak Survey Report Include?

  1. Project Information — project name, facility, survey date, surveyor.
  2. Survey Conditions — operating hours, electricity rate, compressor specific power, control method.
  3. Leak Register — one row per tagged leak with location, flow, cost, and status.
  4. Estimated Energy Opportunity — annual kWh and cost from the baseline leak flows you recorded.
  5. Repair Queue — what should be fixed first, with owner and recommended action.
  6. Repair Status — Open, Planned, Awaiting Re-test, Verified Closed, or Failed Re-test.
  7. Re-test Results — post-repair flow and pass / fail.
  8. Verified Savings — counted only after a passing re-test, not from the original estimate.
  9. Management Summary — counts and dollars a manager can act on without reading every tag.

If you already have a leak list, put it into the Compressed Air Leak Survey Tool so register, queue, re-test, and report stay on the same record.

Compressed Air Leak Survey Report Template

Copy these fields into your air leak inspection report or leak register.

Project and survey conditions

Project

Facility

Survey Date

Surveyor

Operating Hours

Electricity Rate

Compressor Specific Power

Control Method

Leak register (repeat for each leak)

Tag

Area

Asset

Location

Pressure

Detection Method

Measured / Estimated Flow

Annual Energy Loss

Annual Cost

Repair Action

Owner

Status

Re-test Date

Post-repair Flow

Verified Result

Leak Register Fields Explained

Tag
Unique ID on the physical tag and in the register. Without it, repair and re-test cannot be matched.
Area / Asset / Location
Enough for a technician who was not on the survey to find the leak on the first visit.
Pressure
Operating pressure at the leak. The same orifice costs more at higher pressure.
Detection method and flow
Instrument, estimate, or visual. Record the reading you used. The report does not convert dB to SCFM; enter the flow the technician or instrument provided.
Annual energy loss and cost
Planning estimate from flow, specific power, hours, rate, and control assumptions.
Repair action / owner / status
Turns the register into a work list. Status must follow the leak through re-test.
Re-test date, post-repair flow, verified result
Proof the leak is gone. A blank re-test means the savings are still only estimated.

Repair and Re-test Section

Finding a leak is not the end of the survey.

Find → Record → Repair → Re-test → Verify

Completing a repair does not close the leak. Re-test it. If post-repair flow is 0, mark Verified Closed and record Verified Result. If it still leaks, mark Failed Re-test, return it to the repair queue, and do not count Verified Saving.

Failed Re-test cannot be counted as Verified Saving, even when flow dropped. Reduced-but-still-leaking is remaining opportunity.

Management Summary

A manager should be able to read this page without opening the leak register:

  • Total leaks
  • Estimated Opportunity
  • Open Opportunity
  • Repairs completed
  • Awaiting Re-test
  • Verified Closed
  • Failed Re-test
  • Verified Result

Keep Estimated Opportunity and Verified Result in separate lines. Mixing them overstates closed savings.

Build Your Air Leak Survey Report

Instead of maintaining the report manually, use the free UtilRivet Compressed Air Leak Survey Tool to record leaks, prioritize repairs, track re-tests and generate the final report.

Compressed Air Leak Survey Tool